Products

Teletector AD-T

teletector-ad-t

The Teletector Probe 6150AD-t is a portable PTB approved probe for the Dose Rate Meter 6150AD to measure photon radiation (gamma and X-radiation). Two GM counting tubes placed at the telescope’s end serve as detectors covering a very wide dose rate range. The low range tube is placed behind the window in the front of the tube housing and can also detect beta radiation.

 

 

6150 AD-k

 

6150ad-kThe probe 6150AD-k uses a sealed proportional counter which does not require refilling or flushing from external gas reservoirs. Just like the probe 6150AD-17 it is sensitive to alpha, beta, and gamma radiation, however makes surveying larger areas much easier because of the much larger sensitive area.

 

 

 

 

 

6150AD-17

6150ad-17

The detector of the probe 6150AD-17 is a GM counter with a circular end window. With the protective cap applied this probe can be used for general purpose gamma surveys. With the protective cap removed it is sensitive to alpha, beta, and gamma radiation thereby allowing to monitor surface contamination including wipe surveys.

 

 

 

 

 

Dose Rate Meter 6150 AD5automess_

The 6150AD is a PTB approved dose rate meter in a waterproof housing made of aluminium die casting. The built-in GM counting tube serves to measure photon radiation (gamma and X-radiation). As implied by the letters »AD« in its name, the 6150AD provides both analog and digital display with automatic range selection.

 

 

 

 

 

 

Teletector 6112B

teletector-6112b

The Teletector 6112B-100 (indication in Sv/h) and the 6112B-101 (indication in R/h) are the classic models with an analog needle meter. The electronics, although completely redesigned in 2003, are purely analog too, i.e. without a microprocessor. Operation is extremely easy through one single rotary switch with seven positions Off / Battery Condition / five measuring ranges. This means that the range has to be selected manually.

 

 

 

6150 AD- 5/H

teletector-6112

Basically, there are two detectors with different ranges, and the instrument may have »additional functions« or not. This makes a total of four basic models as indicated in the table below (the former 6150AD3 and AD4 models are no longer required because they where replaced with AD5 and AD6). All of the four basic models are available for either the classical quantity Hx or the more modern H*(10).

 

 

 

 

 

Teletector 6112M/H

teletector-6112m

The Teletector 6112M(/H) is PTB approved and provides many additional functions. Model 6112M (without the /H suffix) is designed for the old quantity Hx, and model 6112M/H is for the quantity H*(10). The 6112M(/H) simultaneously measures dose rate, dose, average dose rate, standard deviation of the average, and maximum dose rate.

 

 

 

 

 

VOPV Digital High Volume Air Samplers

vopv-digital-high-volume-air-samplersThe VOPV-12 High-volume air sampler is intended for the sampling of very high
volumes of air and allows for a$follow-up air contamination evaluation. The VOPV-10 High-volume air sampler is intended for air sampling in di&erent applications and can be powered from automobile batteries. Both can be used, for example, for sampling and evaluating radioactive pollutants, dust, etc. in contaminated air. The speci”c use depends on the type of “lter used.

 

 

 

 

DPD Dispenser of Personal Dosimeters

dpd-dispenser-of-personal-dosimetersThe dispensers of personal dosimeters
are devices that enable automatic, fast and controlled issuing of “lm,
thermoluminiscent, optically-stimulated
luminiscent, radiophotoluminiscent or
other similar personal dosimeters. Dosimeter type: TL, RPL, OSL, Film.

 

 

 

 

 

CPM-310 Continuous Particulate Monitor

cpm-310-continuous-particulate-monitorThe CPM-310 continuous particulate monitor is intended for the collection and measurement of radioactive alpha and beta aerosols on “xed “lter. The air can be sampled from both working environments and air ventilation systems.

 

 

 

 

 

 

 

 

MAK-01 Liquid Activity Monitor

mak-01-liquid-activity-monitorMAK-01 is a$submersible liquid activity monitor intended for the measurement of  activity of liquids in various tanks and sumps. It has integrated MCA and small Cs-137 etalon for spectra stabilization. Typically used for the measurement of the volumetric activity of waste liquids from nuclear medicine workplaces, research institutes and nuclear facilities. The measured values are compared with clearance levels for di&erent radionuclides.

 

 

 

 

 

 

 

 

LZJ-22 and LZJ-10 Local Display Units

lzj-22-and-lzj-10-local-display-unitsThe LZJ-22 and LZJ-10 local display units are state-of-the-art devices intended for use with radiation monitoring systems. These devices provide acquisition, processing, displaying, local archiving and transmission to the host system of
signals coming from detectors. A wide variety of “intelligent” or “dumb” probes can be connected locally or remotely using di&erent
interconnections – RS-485, cps, Ethernet, RS-232, USB, current loop, digital and relay I/O, etc. ASU- 50 alarm slave unit can be used for very powerful optical and acoustic alarm signall

 

 

 

 

 

 

Hand-Foot Contamination

Monitors HF series

hand-foot-contaminationThe HF series hand-foot monitors are
intended for alpha, beta and gamma
contamination signalling on hands and feet (depending on the detectors used). Typical usage is at nuclear power plants, radio chemical plants, research institutes, hospitals, etc.

 

 

 

 

 

 

 

 

SKDP series Small Items Contamination Monitors

skdp-series-small-items-contaminationThe SKDP series Small Items Contamination
Monitors are devices for monitoring small objects that may be contaminated by gamma radionuclides. The measured objects are inserted into a$shielded measuring chamber. Two intelligent scintillation detectors are used as standard, up to four additional detectors are available as an option to achieve lower MDA.

 

 

 

 

 

 

Contamination Monitor FCM-02

contamination-monitor-fcm-02The FCM-02 Contamination Monitor
enables the measurement of the surface contamination of radiation  workers, their clothing and working instruments. The measurement is based on a$scintillation detector for alpha, beta and gamma radiation, depending on the detector used. Typically FP series intelligent frisking
probes are connected, with an active area of 100 cm2. Dual phosphor probes with two channel electronics for alpha discrimination are available.

 

 

 

 

 

 

 

MK-30 Sample Analysis System

mk-30-sample-analysis-systemThe Sample Analysis System (MK-30 shielded chamber
and connected PC/notebook) is intended for measuring swipe (smear) and evaporation samples and air “lters. Various detectors can be used for speci”c applications: alpha, beta, gamma, alpha/beta, etc.

 

 

 

 

 

 

 

Waste Assay Monitor„Waste-Scan“ WAM-200 and WAM-201

waste-assay-monitor-waste-scan-wam-200‘Waste-Scan’ monitors are used for the spectrometric characterization of
radioactive waste. They can be used in nuclear power plants, waste repositories,
science facilities, reprocessing plants, etc. for typically LLW measurements or free release (WAM-200) and LLW/ILW measurements or free release (WAM-201). They are intended mainly for the quantitative and qualitative characterization of gamma emitting radionuclides in waste stored in drums of different height, shape and weight. Analysis of non-cylindrical objects is
also a$possible option. As standard, afHPGe detector is used for acquiring the spectra of gamma emitting nuclides contained in waste. The typical measuring parameters (i.e. detection
limits) depend on the type efficiency of detector used.

 

 

 

CPM-300 Continuous Particulate Monitor

cpm-300-continuous-particulateThe CPM-300 monitor is designed to continuously measure the alpha and beta particulates concentration in the air. The air can be sampled directly from working environments, ventilation systems or surrounding environments.

 

 

 

 

 

 

 

 

 

 

Neutron Dose Rate Meters

2The installed MDN-01 can be utilised as part of a large monitoring system with a remote centralized indication, or, in connection with the local display unit, as an autonomous monitor, which provides the data indication locally at the place of measurement with possibility to also remotely transfer data.

 

 

 

 

 

 

 

Hand-Foot Contamination Monitor HF series

hand-foot-contamination-monitorThe HF series hand-foot contamination monitors are intended for the measurement of surface contamination by alpha, beta and gamma emitting radionuclides on hands, feet, and clothing (when equipped with optional frisking probe).

 

 

 

 

 

 

 

 

 

Floor Contamination Monitor “FloorScan” series

floor-contamination-monitorThe monitor is designed for use at nuclear power plants, radiochemical plants, research institutes with reactors, etc. For different workplaces, an appropriate one or two channel model can be utilised, optimized for the measurement of alpha; alpha + beta; alpha + beta + gamma; alpha/beta and alpha/beta + gamma radiation.

 

 

 

 

 

 

 

 

Personnel Exit Monitor Exit Scan-2 series

personnel-exit-monitor

ExitScan-2 is a new type of a two-step whole-body exit monitor designed for checking contamination of personnel leaving controlled areas of nuclear facilities. The monitor checks for the contamination by alpha, beta, and gamma radiation emitting radionuclides (depending on the detectors used).

 

 

 

 

 

 

 

 

 

Laundry Contamination Monitors LCM-300 series

laundry-contamination-monitorsThe Laundry Contamination Monitors LCM-300 series are mobile devices that primarily serve for checking contamination of washed, dried, and laid- out laundry originating from areas where it could have been in contact with alpha, beta and/or gamma radionuclides. They can also be used for checking contamination of other items of suitable size.

 

 

 

 

 

MK-30P Measuring Chamber

3The MK-30P measuring chamber with lead shield thickness of 30 mm is designed for measuring activity with high precision and reliability. The device is used in nuclear power plants, radiochemical plants, research institutes, and elsewhere. It is designed for activity measurements of wipe tampons, evaporated samples and air filters. Various detectors (e.g. beta, gamma, and/or alpha/beta) can be used. An alpha/beta detector is standard. The device can also be used for tutorial purposes.

 

 

 

 

 

 

 

 

Radcount-2S Display Unit

radcount-2s-display-unitRadcount-2S is a versatile dual channel display unit, which can be used with variety of VF’s smart detectors. When connected with SFP series frisking probe it can serve as a portable hand-held contamination monitor of alpha, beta and gamma emitting radionuclides. The surfaces of various objects can be measured, such as: walls, floors, tables, pallets, drums, hands, feet and clothing.

 

 

 

 

 

 

 

 

Smart Frisking Probes SFP-100 series

smart-frisking-probesThe SFP-100 smart frisking probe is a hand-held 100cm2 detector intended for alpha, beta and gamma surface contamination detection. The smart frisking probe, when connected to a suitable display unit, can be used as a body, clothing or material surface contamination monitor. It can also be used as an additional clothing contamination probe connected to the Hand-Foot Monitor, Hand Monitor and other installed VF monitors. The probe has several variants for single or dual channel detection of alpha, beta and gamma radiation.

 

 

 

 

smd01-1-dispenser-dilutor

smd01-1-dispenser-dilutorSMD01-1 Dispenser & Dilutor handles liquid sample precisely. It consists of software, one pieces control units and probe. It has

functions of semi-automatically dispensing and diluting. SMD01-1 features accurate control, easy and reliable operation to match the requirements to prepare liquid sample for analytical laboratory. SMD01-1 completely replaces the traditional manual operation of dispensing and diluting and widely used in blood analysis, emulsion analysis, chemical analysis, food analysis, urine analysis.

 

 

 

 

329 Laundry Monitoring System

laundrymonitor

The Model ‘IMPEX 329’ Laundry Monitoring System is LND Pancake 8767 based detection system, intended for automatic monitoring of beta-gamma contamination on clothing or other light articles presumed to be free of radioactivity, or within release or reuse limits. A conveyor belt carries articles between two sets of detector arrays. An audible alarm will sound when contamination exceeds the given alarm set point.

 

 

 

 

Modular under water Gamma Monitoring system

modular-under-water-gamma-monitoring-systemThe technical solutions characterizing the SMU-01NV permit low power consumption and small dimensions and weight. Easy operation and very limited need of operator’s interventions are among the advanced characteristics as well as measurement’s precision and reliability thanks to proprietary algorithms, auto-test and auto-calibration procedures, automatic failure detection and automatic control of significant parameters, including response time between two programmable values.